Cleaning Trial Summary

Segment
:: TSR #13-A-196

 

Customer Objective

The customer was looking to improve their cleaning performance, automate their cleaning process and reduce rework and reject rate.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160⁰F
Industry
Time Required
Industry
OEM parts manufacture
Time Required
15 minutes
Segment
Substrate
Auto Dealership
Aluminum Steel
Soil
, Grime
Description of Part(s)
Description of Part
Steel connectors
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (SK Blackstone model 6315)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommended using either 5% by volume ArmaKleen™ 4 in 1 Cleaner, 10% by volume ArmaKleen™ M-Aero at 160⁰F in an Ultrasonic Washer for a minimum of 15 minutes.