Cleaning Trial Summary
Customer Objective
The customer wants to automate their cleaning process and recover scrap parts.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160⁰F
Industry
Time Required
Industry
Manufacturing
Time Required
2 hours
Segment
Substrate
Auto Retail
Steel
Soil
Oil, Shop Dirt
Description of Part(s)
Description of Part
Steel filters, steel plate, steel connector arm
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
- Spray Washer (TL3, FL250, FL500)
- Ultrasonic Washer (SK6315 – Blackstone model 3523)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 5% by volume 4 in 1 Cleaner in a Spray Washer or an Ultrasonic Washer at 160⁰F for 2 hours. Both machines could be used but a Spray Washer did better on the filters.