Cleaning Trial Summary
Customer Objective
              The customer was looking to improve their cleaning performance and automat their cleaning process.
            Cleaning Trial Type
          
          
            Temperature
          
        
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Aqueous
                     
                     
          
          
          Temperature
              160⁰F
          
            Industry
          
          
            Time Required
          
        Industry
              Remanufacturing
          Time Required
              3.5 – 8 hours
          
            Segment
          
          
            Substrate
          
                   
           
                       
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Fabricated Metal Product
                     
                     
                    
          
        
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Steel
                     
                     
                      
          
        
            Soil
          
        
                                                                                                                                                                                                                                                                                                            ,                     Baked on Carbon                                                    
          
        
            Description of Part(s)
          
        Description of Part
              Steel cuffs
          
            Cleaner Used
          
        5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
10% by volume ARMAKLEEN™ M-301
            Machine Used
          
  Machine Used
              - Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000)
 - Ultrasonic Washer (SK 6315)
 - Spray Under Immersion Washer (Graymills T12, Graymills T24, SK 81.8 w/SUI)
 
            Post Cleaning
          
        Post Cleaning
              Fresh water rinse followed by air pressure drying.
            Recommendation to Customer
          
        Recommendation
              The ArmaKleen Technical Center recommended using 10% by volume ArmaKleen™ M-301 at 160⁰F in an Ultrasonic Washer for a minimum of 3.5 hours.