Cleaning Trial Summary

:: TSR #13-A-076

 

Customer Objective

The customer was looking to improve their cleaning performance and automat their cleaning process.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160⁰F
Industry
Time Required
Industry
Remanufacturing
Time Required
3.5 – 8 hours
Segment
Substrate
Fabricated Metal Product
Steel
Soil
, Baked on Carbon
Description of Part(s)
Description of Part
Steel cuffs
Cleaner Used
Machine Used
Machine Used
  1. Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000)
  2. Ultrasonic Washer (SK 6315)
  3. Spray Under Immersion Washer (Graymills T12, Graymills T24, SK 81.8 w/SUI)
Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommended using 10% by volume ArmaKleen™ M-301 at 160⁰F in an Ultrasonic Washer for a minimum of 3.5 hours.