Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #17-A-174

 

Customer Objective

Improve cleaning performance, automate cleaning process

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Transportation Products Manufacturing
Time Required
30 minutes
Segment
Substrate
Miscellaneous Manufacturing
Steel
Soil
Grease Mold release, Plastic out-gas residues
Description of Part(s)
Description of Part
Molds
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning
Post Cleaning

Fresh water rinse and air pressure drying

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 30 minutes