Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, automate their cleaning process and reduce their cleaning costs.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Packaging Manufacturer
Time Required
1 hour
Segment
Substrate
Miscellaneous Manufacturing
Steel
Soil
Grease Oil, Rust/Oxides
Description of Part(s)
Description of Part
Two steel dies/molds and one steel connector with a steel gear wheel.
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
Ultrasonic Washer (SK Blackstone Model 6315)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 1 hour.