Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, automate their cleaning process, reduce rework and reject rate, reduce their cleaning costs and eliminate hazardous chemical/waste.
Cleaning Trial Type
Temperature
Aqueous
Temperature
140°F
Industry
Time Required
Industry
Fastener Distribution
Time Required
15-30 minutes
Segment
Substrate
Miscellaneous Manufacturing
Brass
Soil
Diesel Oil Grease Grime Oil Rust/Oxides, Shop Dirt
Description of Part(s)
Description of Part
Thirteen 360-brass connectors
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 15-30 minutes.