Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, automate their cleaning process and eliminate hazardous chemical/waste.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Electrical component Manufacturering
Time Required
0.25-1 hour
Segment
Substrate
Fabricated Metal Product
Stainless Steel
Soil
Cutting Fluids Drawing Lube Oil, Shop Dirt
Description of Part(s)
Description of Part
Six stainless steel transmitter/connectors
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
· Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/SUI)
· Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 15 minutes to 1 hour or a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 150°F in a Spray-Under Immersion Washer for a minimum of 15 minutes to 1 hour.