Skip to main content
Before
TSR #16-A-015
After

Cleaning Trial Summary

:: TSR #16-A-015

 

Customer Objective

The customer was looking to improve their cleaning performance, automate their cleaning process and reduce their cleaning costs.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Race motor Manufacturer
Time Required
1 hour
Segment
Substrate
Electrical Manufacturing
Steel
Soil
Baked on Carbon Grease Grime, Oil
Description of Part(s)
Description of Part
A steel engine bracket and a steel engine intake cover
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 1 hour.