Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, automate their cleaning process, reduce rework and reject rate, reduce their cleaning costs and eliminate hazardous chemicals and waste.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Electro Motor Manufacturer
Time Required
1 hour
Segment
Substrate
Mechanical & Equipment Service
Steel
Soil
Baked on Carbon Cutting Fluids Drawing Lube Grease Grime Oil, Rust/Oxides
Description of Part(s)
Description of Part
Assortment of steel plates/covers
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000
Post Cleaning
Post Cleaning
Fresh water rinsing followed by air pressure drying. Several areas of orange steel/iron cover plate were brush with a stainless steel bristle brush during fresh water rinse and air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in a Spray Washer for a minimum of 1 hour.