Cleaning Trial Summary

Segment
:: TSR #16-A-011

 

Customer Objective

The customer was looking to improve their cleaning performance, automate their cleaning process and clean mixed metals together.

Cleaning Trial Type
Temperature
Aqueous
Temperature
150°F
Industry
Time Required
Industry
Edile oil manufacturing
Time Required
15 minutes to 1 hour
Segment
Substrate
Food
Aluminum Copper Stainless Steel Steel
Soil
, Olive Oil
Description of Part(s)
Description of Part
Gear and injectors
Cleaner Used
Machine Used
Machine Used

Spray Under Immersion Washer (Graymills T12, Graymills T24, SK 81.8 w/SUI)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.  The gear was lightly brushed with a nylon bristle brush during the fresh water rinse.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 150°F in a Spray Under Immersion Washer for a minimum of 30 minutes to 1 hour.