Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #15-A-233

 

Customer Objective

The customer was looking to improve their cleaning performance, automate their cleaning process, reduce rework and reject rate, reduce their cleaning costs and eliminate hazardous chemicals and waste.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Transmission Repair
Time Required
1 hour
Segment
Substrate
Auto Maintenance
Aluminum Copper Plastic Stainless Steel Steel
Soil
Adhesive Baked on Carbon Cutting Fluids Glue Grease Grime Oil, Rust/Oxides
Description of Part(s)
Description of Part
Transmission parts
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (Blackstone  model SK 6315)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying

Recommendation to Customer
Recommendation

 The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 1 hour.