Cleaning Trial Summary

:: TSR #15-A-229

 

Customer Objective

The customer was looking to improve their cleaning performance and reduce their cleaning costs.

Cleaning Trial Type
Temperature
Aqueous
Temperature
150°F to 160°F
Industry
Time Required
Industry
Auto parts manufacturing
Time Required
15 minutes to 1 hour
Segment
Substrate
Fabricated Metal Product
Aluminum
Soil
Oil, Paraffin
Description of Part(s)
Description of Part
Coupons
Cleaner Used
Machine Used
Machine Used

1.       Ultrasonic Washer (Blackstone SK 6315)

2.       Spray Under Immersion Washer (Graymills T12, Graymills T24, SK 81.8 w/SUI)

3.       Spray Washer (JRI FL250, JRI FL500, JRI TL3, Better Engineering G-2000)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner or 5% ArmaKleen M-HP-2 at 160°F in either an Ultrasonic Washer or a Spray Washer for a minimum of 15 to 30 minutes.