Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #15-A-223

 

Customer Objective

The customer was looking to improve their cleaning performance, automate their cleaning process and reduce rework and reject rate.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Paper manufacturing
Time Required
1 to 2 hours
Segment
Substrate
Machine Manufacturing
Aluminum Rubber Stainless Steel Steel
Soil
Adhesive Cutting Fluids Glue Grease Grime Oil, Silicone
Description of Part(s)
Description of Part
Housing units
Cleaner Used
Machine Used
Machine Used

1.       Spray Washer (JRI FL250, JRI FL500, JRI TL3, Better Engineering G-2000)

2.       Ultrasonic Washer (Blackstone SK 6315)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.  Several areas were brushed with a nylon bristle brush during the fresh water rinse.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 2 hours.