Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance and reduce rework and reject rate.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Transmission Remanufacturing
Time Required
15 to 30 minutes
Segment
Substrate
Auto Maintenance
Brass
Plastic
Rubber
Stainless Steel
Steel
Soil
, Oil
Description of Part(s)
Description of Part
Plug
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
Ultrasonic Washer (Blackstone SK 6315)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 15 to 30 minutes.