Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #15-A-208

 

Customer Objective

The customer was looking to improve their cleaning performance and reduce rework and reject rate.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Transmission Remanufacturing
Time Required
15 to 30 minutes
Segment
Substrate
Auto Maintenance
Brass Plastic Rubber Stainless Steel Steel
Soil
, Oil
Description of Part(s)
Description of Part
Plug
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (Blackstone SK 6315)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 15 to 30 minutes.