Skip to main content
Before
After

Cleaning Trial Summary

Segment
:: TSR #15-A-204

 

Customer Objective

The customer was looking to improve their cleaning performance and automate their cleaning process

Cleaning Trial Type
Temperature
Aqueous
Temperature
150 – 160°F
Industry
Time Required
Industry
Construction
Time Required
30 minutes to 1 hour
Segment
Substrate
Construction
Steel
Soil
Grime Rust/Oxides, Shop Dirt
Description of Part(s)
Description of Part
Steel connectors
Cleaner Used
Machine Used
Machine Used

·         Spray Under Immersion Washer (Graymills T12, Graymills T24, SK 81.8 w/SUI)

·         Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer
Recommendation

 The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 150 – 160°F in either a Spray Under Immersion washer or an Ultrasonic Washer for a minimum of 30 minutes to 1 hour.