Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #13-A-215

 

Customer Objective

The customer was looking to improve their cleaning performance, reduce rework and reject rate, reduce their cleaning costs and eliminate hazardous chemicals and waste.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160⁰F
Industry
Time Required
Industry
OEM Parts Manufacturing
Time Required
15 to 30 minutes
Segment
Substrate
Fabricated Metal Product
Aluminum
Soil
Cutting Fluids Oil, Shop Dirt
Description of Part(s)
Description of Part
Aluminum brackets
Cleaner Used
Machine Used
Machine Used

Spray Under Immersion Washer (Graymills T12, Graymills T24, SK 81.8 w/SUI)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160⁰F in a Spray Under Immersion Washer for a minimum of 15 to 30 minutes.