Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #19-A-114

 

Customer Objective

Improve cleaning performance

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Maching
Time Required
30 minutes
Segment
Substrate
Electrical Manufacturing
Iron Steel
Soil
Baked on Carbon Cutting Fluids Grease, Oil
Description of Part(s)
Description of Part
Engine components
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™ 4-in-1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 30 minutes