Cleaning Trial Summary
Customer Objective
Improve cleaning performance and automate cleaning process
Cleaning Trial Type
Temperature
Aqueous
Temperature
150°F, 160°F
Industry
Time Required
Industry
Membrane Separators Manufacturing
Time Required
2 hours
Segment
Substrate
Chemical Manufacturing
Steel
Soil
, Anti-seize
Description of Part(s)
Description of Part
Bolts
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
- Spray Under Immersion (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
- Ultrasonic (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 1-2 hours