Cleaning Trial Summary
Customer Objective
Improve cleaning performance, automate cleaning process, reduce rework/reject rate, recover scrap parts
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
LED light manufacturing
Time Required
4-8 hours
Segment
Substrate
Electrical Manufacturing
Brass
Soil
Baked on Carbon, Baked on gases
Description of Part(s)
Description of Part
Dies
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
10% by volume M-100 BCR (Baked on Carbon Remover)
Machine Used
Machine Used
Ultrasonic (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure drying
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-100 BCR at 160°F in an Ultrasonic Washer for a minimum of 4 hours