Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #17-A-197

 

Customer Objective

Improve cleaning performance, automate cleaning process, reduce rework/reject rate, recover scrap parts

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
LED light manufacturing
Time Required
4-8 hours
Segment
Substrate
Electrical Manufacturing
Brass
Soil
Baked on Carbon, Baked on gases
Description of Part(s)
Description of Part
Dies
Cleaner Used
Machine Used
Machine Used

Ultrasonic (SK Blackstone 6315)

Post Cleaning
Post Cleaning

Fresh water rinse and air pressure drying

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™  M-100 BCR at 160°F in an Ultrasonic Washer for a minimum of 4 hours