Cleaning Trial Summary
Customer Objective
The customer was looking to automate their cleaning process
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Hydraulic Cylinder Manufacturer
Time Required
30 minutes
Segment
Substrate
Machine Manufacturing
Stainless Steel
Soil
Cutting Fluids Grime, Oil
Description of Part(s)
Description of Part
a stainless steel connector/die
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in a TL-Spray Washer for a minimum of 30 minutes.