Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance and automate their cleaning process.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Security Hardware Manufacturer
Time Required
15 – 30 minutes
Segment
Substrate
Fabricated Metal Product
Aluminum
Brass
Steel
Soil
, Buffing compound
Description of Part(s)
Description of Part
An assortment of polished brass door parts and four #6063-anodized aluminum plates
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
- Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000
- Ultrasonic Washer (SK Blackstone Model 6315)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer or a Spray Washer for a minimum of 15-30 minutes.