Cleaning Trial Summary
::
TSR #17-A-022
Customer Objective
The customer was looking to improve their cleaning performance.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Electronic Remanufacturer
Time Required
15 minutes
Segment
Substrate
Aluminum
Soil
Adhesive Baked on Carbon Glue Grime, Oil
Description of Part(s)
Description of Part
Two cast aluminum HD Transmission Circuit Boards. One of the circuit boards has assorted electronic connections attached.
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
- Spray-Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/SUI)
- Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000)
Post Cleaning
Post Cleaning
Openings were lightly brushed with a nylon bristle brush during fresh water rinse followed air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in a Spray-Under Immersion Washer for a minimum of 15 minutes or a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in a Spray Washer for a minimum of 15 minutes.