Customer Objective

The customer was looking to improve their cleaning performance and reduce rework and reject rate

Cleaning Trial Type
Temperature
Aqueous
Temperature
150°F
Industry
Time Required
Industry
Precision Manufacturing and Assembling
Time Required
15 – 30 minutes
Segment
Substrate
Machine Manufacturing
Aluminum Brass
Soil
Cutting Fluids Oil, Shop Dirt
Description of Part(s)
Description of Part
Two aluminum connectors and seven brass connectors
Cleaner Used
Machine Used
Machine Used

Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/SUI)

Post Cleaning
Post Cleaning

Fresh water rinsing followed by air pressure drying

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 150°F in a Spray-Under Immersion Washer for a minimum of 15-30 minutes