Skip to main content
17a007before.jpg
Before
17a007after.jpg
After

Cleaning Trial Summary

Segment
:: TSR #17-A-007

 

Customer Objective

The customer was looking to improve their cleaning performance and automate their cleaning process.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Printing Label Manufacturer
Time Required
15 minutes
Segment
Substrate
Printing
Aluminum Stainless Steel
Soil
Description of Part(s)
Description of Part
stainless steel ink tray with aluminum brackets
Cleaner Used
Machine Used
Machine Used

Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000)

Post Cleaning
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in a Spray Washer for a minimum of 15 minutes.