Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, reduce rework and reject rate and eliminate soap residue.
Cleaning Trial Type
Temperature
Aqueous
Temperature
150°F
Industry
Time Required
Industry
Racing parts manufacture
Time Required
15 to 30 minutes
Segment
Substrate
Dealership
Aluminum
Brass
Copper
Plastic
Rubber
Stainless Steel
Steel
Soil
Adhesive Glue Oil, Shop Dirt
Description of Part(s)
Description of Part
Pump tubes and connectors
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
Spray Under Immersion Washer (Graymills T12, Graymills T24, SK 81.8 w/SUI)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 150°F in a Spray Under Immersion Washer for a minimum of 15 – 30 minutes.