Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #16-A-037

 

Customer Objective

The customer was looking to improve their cleaning performance, clean mixed metals together and eliminate hazardous chemicals and waste.

Cleaning Trial Type
Temperature
Aqueous
Temperature
150°F – 160°F
Industry
Time Required
Industry
Parts Manufacturing
Time Required
15 minutes
Segment
Substrate
Machine Manufacturing
Soil
Cutting Fluids Grease Grime Oil, Shop Dirt
Description of Part(s)
Description of Part
Machined parts
Cleaner Used
Machine Used
Machine Used

1.       Ultrasonic Washer (Blackstone SK 6315)

2.       Spray Under Immersion Washer (Graymills T12, Graymills T24, SK 81.8 w/SUI)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 150°F in a Spray Under Immersion Washer for a minimum of 15 minutes.