Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #16-A-018

 

Customer Objective

The customer was looking to improve their cleaning performance and automate their cleaning process.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
OEM Gardening Supply Manufacturing
Time Required
2 hours
Segment
Substrate
Fabricated Metal Product
Soil
Hardened Fiber Oil Shop Dirt, Wax
Description of Part(s)
Description of Part
Fiber pot mesh mold
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (Blackstone SK 6315)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 2 hours.