Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #15-AP-214

 

Customer Objective

The customer was looking to improve their cleaning process, reduce rework and reject rate and eliminate hazardous chemicals and waste.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Manufacturing
Time Required
8 hours
Segment
Substrate
Fabricated Metal Product
Rubber Stainless Steel Steel
Soil
Adhesive Glue, Oil
Description of Part(s)
Description of Part
Nozzles and connectors
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (Blackstone SK6315)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.  Several threaded areas where lightly brushed with a stainless steel bristle brush during the fresh water rinse.

Recommendation to Customer
Recommendation

 The ArmaKleen Technical Center recommended using either 5% by volume ArmaKleen™ 4 in 1 Cleaner or 10% by volume ArmaKleen™ M-301 at 160°F in an Ultrasonic Washer for a minimum of 2 to 8+ hours.