Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, automate their cleaning process and reduce rework and reject rate.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Mold manufacturing
Time Required
15 to 30 minutes
Segment
Substrate
Machine Manufacturing
Aluminum
Soil
Aluminum dust Cutting Fluids, Silicone
Description of Part(s)
Description of Part
Mold/plate, plates, connector roller, brace
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160°F in a Spray Washer for a minimum of 15 – 30 minutes.