Before
After

Cleaning Trial Summary

Auto Dealership :: TSR #15-A-219

 

The customer was looking to improve their cleaning performance, automate their cleaning process and eliminate hazardous chemicals and waste.

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Turbocharger repair/ remanufacturing
2 hours
Segment
Substrate
Auto Dealership
Stainless Steel
Soil
Baked on Carbon, Fuel deposits
Description of Part(s)
Turbine blades
Cleaner Used

5% by volume ARMAKLEEN™ 4 in 1 Cleaner

10% by volume ARMAKLEEN™ M-301

Machine Used

Ultrasonic Washer (Blackstone SK 6315)

Post Cleaning

 Fresh water rinse followed by air pressure drying.

Recommendation to Customer

The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 2 hours or using 10% by volume ArmaKleen™ M-301 at 160°F in an Ultrasonic Washer for a minimum of 2 hours.