Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, automate their cleaning process and eliminate hazardous chemicals and waste.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Turbocharger repair/ remanufacturing
Time Required
2 hours
Segment
Substrate
Auto Dealership
Stainless Steel
Soil
Baked on Carbon, Fuel deposits
Description of Part(s)
Description of Part
Turbine blades
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
10% by volume ARMAKLEEN™ M-301
Machine Used
Machine Used
Ultrasonic Washer (Blackstone SK 6315)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 2 hours or using 10% by volume ArmaKleen™ M-301 at 160°F in an Ultrasonic Washer for a minimum of 2 hours.