Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, automate their cleaning process and eliminate hazardous chemicals and waste.
Cleaning Trial Type
Temperature
Aqueous
Temperature
150°F – 160°F
Industry
Time Required
Industry
Electronics component manufacturing
Time Required
10 to 20 minutes
Segment
Substrate
Mechanical & Equipment Service
Aluminum
Brass
Copper
Glass
Plastic
Rubber
Stainless Steel
Steel
Soil
Adhesive Cutting Fluids Drawing Lube Glue Grease Grime Oil Rust/Oxides Shop Dirt, Silicone
Description of Part(s)
Description of Part
Frames, filters, circuit boards
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
1. Agitating Immersion Washer (SK 81.8, Graymills T12, Graymills T24)
2. Ultrasonic Washer (Blackstone SK 6315)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner in an Agitating Immersion Washer at 150°F for a minimum of 15 to 30+ minutes.