Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, automate their cleaning process, reduce their cleaning costs and eliminate hazardous chemicals and waste.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160⁰F
Industry
Time Required
Industry
OEM Electrical Component Manufacturing
Time Required
10 to 20 minutes
Segment
Substrate
Electrical Manufacturing
Glass
Steel
Soil
Grease, Soldering flux
Description of Part(s)
Description of Part
Steel RF filters with glass insulating connections
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
- Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000)
- Agitating Immersion Washer (SK 81.8, Graymills T12, Graymills T24)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160⁰F in a Spray Washer for a minimum of 20 to 30 minutes.