Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, reduce rework and reject rate and remove soap residue from the cleaning process.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160⁰F
Industry
Time Required
Industry
Diesel Engine Remanufacturing
Time Required
30 to 60 minutes
Segment
Substrate
Auto Maintenance
Steel
Soil
Baked on Carbon Grime, Oil
Description of Part(s)
Description of Part
Steel diesel engine injector parts
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
Ultrasonic Washer (Blackstone SK 6315)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160⁰F in an Ultrasonic Washer for a minimum of 30 minutes.