

Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance and automat their cleaning process.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160⁰F
Industry
Time Required
Industry
Remanufacturing
Time Required
3.5 – 8 hours
Segment
Substrate
Fabricated Metal Product
Steel
Soil
, Baked on Carbon
Description of Part(s)
Description of Part
Steel cuffs
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
10% by volume ARMAKLEEN™ M-301
Machine Used
Machine Used
- Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000)
- Ultrasonic Washer (SK 6315)
- Spray Under Immersion Washer (Graymills T12, Graymills T24, SK 81.8 w/SUI)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 10% by volume ArmaKleen™ M-301 at 160⁰F in an Ultrasonic Washer for a minimum of 3.5 hours.