Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning process, automate their cleaning process, reduce rework and reject rate and recover scrap parts.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160⁰F
Industry
Time Required
Industry
Copier remanufacturing
Time Required
2 hours
Segment
Substrate
Retail Trade
Aluminum
Plastic
Stainless Steel
Steel
Soil
Grease Grime Oil Rust/Oxides Shop Dirt, Toner Residue
Description of Part(s)
Description of Part
Copier machine parts
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
Machine Used
Machine Used
- Spray Under Immersion Washer (T12, T24, 40.1, 81.8 w/ SUI)
- Agitating Immersion Washer (81.8, T12, T24)
- Spray Washer (TL3, FL250, FL500)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160⁰F in a Spray Under Immersion Washer, an Agitating Immersion Washer or a Spray Washer for a minimum of 2 hours.