Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, automate their cleaning process, reduce rework and reject rate and eliminate hazardous chemicals and waste.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160⁰F
Industry
Time Required
Industry
Food Manufacture
Time Required
8 hours
Segment
Substrate
Fabricated Metal Product
Steel
Soil
Grime Oil Peanut husks, Peanut oil
Description of Part(s)
Description of Part
Steel tubes
Cleaner Used
5% by volume ARMAKLEEN™ 4 in 1 NF Cleaner
10% by volume ARMAKLEEN™ M-301
Machine Used
Machine Used
Spray Washer (TL3, FL250, FL500)
Agitating Immersion Washer (81.8, T12, T24)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 10% by volume ArmaKleen™ M-301 at 160⁰F in an Agitating Immersion Washer for a minimum of 8 hours.