Cleaning Trial Summary
Customer Objective
              Improve cleaning performance, automate cleaning process, reduce rework and reject rate, clean mixed metals together, reduce cleaning costs, utilize one cleaner for all types of metals
            Cleaning Trial Type
          
          
            Temperature
          
        
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Aqueous
                     
                     
          
          
          Temperature
              160°F
          
            Industry
          
          
            Time Required
          
        Industry
              Machine Manufacturing
          Time Required
              15-30 minutes
          
            Segment
          
          
            Substrate
          
                   
           
                       
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Fabricated Metal Product
                     
                     
                    
          
        
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Aluminum
                     Copper/brass
                     Iron
                     Stainless Steel
                     Steel
                     
                     
                      
          
        
            Soil
          
        
                                                                                                                                                                                                                                                                                                                                Cutting Fluids,                     Oil                                                    
          
        
            Description of Part(s)
          
        Description of Part
              Assortment of screws, nuts, bolts
          
            Cleaner Used
          
        5% by volume ArmaKleen™ Bio 24
            Machine Used
          
  Machine Used
              - Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
 - Ultrasonic Washer (SK Blackstone 6315)
 
            Post Cleaning
          
        Post Cleaning
              Fresh water rinse and air pressure dried
            Recommendation to Customer
          
        Recommendation
              The ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™ BIO-24 at 160°F in a Spray Under Immersion Washer for a minimum of 15 to 30 minutes or a 5% by volume solution of ArmaKleen™ BIO-24 at 160°F in an Ultrasonic Washer for a minimum of 15 to 30 minutes