Cleaning Trial Summary
Customer Objective
Improve cleaning performance and reduce cleaning costs
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Metal Manufacturing
Time Required
15-60 minutes
Segment
Substrate
Fabricated Metal Product
Copper/brass
Soil
Drawing Lube, Oil
Description of Part(s)
Description of Part
Small caps
Cleaner Used
5% by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse followed by drying in an incubator at 108°C
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™ BIO-24 at 160°F in an Ultrasonic Washer for a minimum of 15 to 60 minutes