Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #19-A-105

 

Customer Objective

Improve cleaning performance and reduce cleaning costs

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Metal Manufacturing
Time Required
15-60 minutes
Segment
Substrate
Fabricated Metal Product
Copper/brass
Soil
Drawing Lube, Oil
Description of Part(s)
Description of Part
Small caps
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning
Post Cleaning

Fresh water rinse followed by drying in an incubator at 108°C

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™ BIO-24 at 160°F in an Ultrasonic Washer for a minimum of 15 to 60 minutes