Cleaning Trial Summary
Customer Objective
              Automate cleaning process and recover scrap parts
            Cleaning Trial Type
          
          
            Temperature
          
        
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Aqueous
                     
                     
          
          
          Temperature
              160°F
          
            Industry
          
          
            Time Required
          
        Industry
              Heating and Cooling
          Time Required
              6 hours
          
            Segment
          
          
            Substrate
          
                   
           
                       
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Machine Manufacturing
                     
                     
                    
          
        
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Aluminum
                     Copper/brass
                     
                     
                      
          
        
            Soil
          
        
                                                                                                                                                                                                                                                                                                                                Aluminum flux/scale,                     Baked on Carbon                                                    
          
        
            Description of Part(s)
          
        Description of Part
              Torch heads
          
            Cleaner Used
          
        10% by volume ARMAKLEEN™ Rust Remover
10% by volume M-100 BCR (Baked on Carbon Remover)
            Machine Used
          
  Machine Used
              Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
            Post Cleaning
          
        Post Cleaning
              Fresh water rinse and air pressure dried
            Recommendation to Customer
          
        Recommendation
              The ArmaKleen Technical Center recommends using a 10% by volume of ArmaKleen™ Rust Remover at 160°F in a Spray Under Immersion Washer for a minimum of 6 hours