Skip to main content
Before
After

Cleaning Trial Summary

 

Customer Objective

Improve cleaning performance, automate cleaning process, reduce rework and reject rate, reduce cleaning costs

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Aerospace
Time Required
1 hour
Segment
Substrate
Transportation Equipment Manufacturing
Aluminum Iron Steel
Soil
Baked on Carbon Grease Grime, Oil
Description of Part(s)
Description of Part
Turbocharger components
Cleaner Used
Machine Used
Machine Used
  • Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3)
  • Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 10% by volume solution ArmaKleen™ M-100BCR at 160°F in an Ultrasonic Washer for a minimum of 1 hour