Cleaning Trial Summary
Customer Objective
Improve cleaning performance, automate cleaning process, reduce rework and reject rate, eliminate hazardous chemicals.waste, reduce VOCs, reduce cleaning costs
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Connectors Manufacturing
Time Required
15 minutes
Segment
Substrate
Electrical Manufacturing
Aluminum
Copper/brass
Stainless Steel
Soil
Cutting Fluids, Oil
Description of Part(s)
Description of Part
Connector fittings
Cleaner Used
10% by volume ARMAKLEEN™ MM-Dip
Machine Used
Machine Used
- Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8)
- Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ MM-Dip at 160°F in a Spray Under Immersion Washer for a minimum of 15 minutes