Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #13-P-058

 

Customer Objective

The customer was looking to improve their cleaning performance, automate their cleaning process, reduce rework and reject rate and reduce their cleaning costs.

Cleaning Trial Type
Temperature
Paint
Temperature
160⁰F (Spray Washer), 150⁰F (Immersion Washer)
Industry
Time Required
Industry
Elevator Manufacture
Time Required
12 hours
Segment
Substrate
Miscellaneous Manufacturing
Steel
Soil
Paint (Acrylic powder coat), Paint (Epoxy powder coat)
Description of Part(s)
Description of Part
Steel paint hooks
Cleaner Used
Machine Used
Machine Used
  • Spray Washer (TL3, FL250, FL500)
  • Agitating Immersion Washer (81.8, T12, T24)
Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommended using 100% by volume ArmaKleen™ Paint and Ink Remover at 160⁰F in a Spray Washer for a minimum of 12 hours.