Cleaning Trial Summary
Customer Objective
Improve cleaning performance, reduce cleaning costs, recover scrap parts
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Remanufacturing
Time Required
1-2 hours
Segment
Substrate
Auto Retail
Aluminum
Steel
Soil
Oil, Rust/Oxides
Description of Part(s)
Description of Part
Housing units/connectors
Cleaner Used
5% by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried, followed by drying in an incubator at 220°F
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in a Spray Washer for a minimum of 1-2+ hours