Cleaning Trial Summary
Customer Objective
Improve cleaning performance, automate cleaning process, reduce rework and reject rate
Cleaning Trial Type
Temperature
Aqueous
Temperature
150°F
Industry
Time Required
Industry
Watch Parts Manufacturing
Time Required
15 minutes-2 hours
Segment
Substrate
Non-metal Manufacturing
Stainless Steel
Steel
Soil
Grease Grime, Oil
Description of Part(s)
Description of Part
Assortment of cylinders, disks, rings
Cleaner Used
5% by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
Spray Under Immersion (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 150°F in a Spray-Under Immersion Washer for a minimum of 15 minutes to 2 hours