Cleaning Trial Summary
Customer Objective
Improve cleaning performance, automate cleaning process, reduce cleaning costs
Cleaning Trial Type
Temperature
Aqueous
Temperature
150°F
Industry
Time Required
Industry
Welding Products
Time Required
30 minutes to 1 hour
Segment
Substrate
Machine Manufacturing
Copper
Stainless Steel
Soil
Cutting Fluids Oil, Shop Dirt
Description of Part(s)
Description of Part
Connectors
Cleaner Used
5% by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
Spray Under Immersion (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 150°F in a Spray-Under Immersion Washer for a minimum of 30 minutes to 1 hour