Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #18-A-043

 

Customer Objective

Improve cleaning performance, automate cleaning process, reduce cleaning costs

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Metal Machine Parts Manufacturing
Time Required
15 minutes
Segment
Substrate
Machine Manufacturing
Steel
Soil
Cutting Fluids Grinding swarf, Oil
Description of Part(s)
Description of Part
Brackets/guides
Cleaner Used
Machine Used
Machine Used
  • Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
  • Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in a Spray-Under Immersion Washer or in an Ultrasonic Washer for a minimum of 15 minutes