Cleaning Trial Summary
Customer Objective
Improve cleaning performance and automate cleaning process
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Metalworking
Time Required
1 hour
Segment
Substrate
Fabricated Metal Product
K500
Monel QQN-281
Stainless Steel
Soil
Cutting Fluids Grease, Molykote P37
Description of Part(s)
Description of Part
Process machine components
Cleaner Used
10% by volume ARMAKLEEN™ M-HP-2
Machine Used
Machine Used
- Ultrasonic Washer (SK Blackstone 6315)
- Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3)
Post Cleaning
Post Cleaning
Some parts were rinsed with fresh water and air pressure dried, while other parts were only air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-HP-2 at 160°F in an Ultrasonic Washer for a minimum of 1 hour or a 10% by volume solution of ArmaKleen™ M-HP-2 at 160°F in a Spray Washer for a minimum of 1 hour, both with a fresh water rinse