Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #16-P-042

 

Customer Objective

The customer was looking to improve their cleaning performance.

Cleaning Trial Type
Temperature
Paint
Temperature
160°F
Industry
Time Required
Industry
Automotive parts manufacturer
Time Required
4 hours
Segment
Substrate
Auto Maintenance
Steel
Soil
, Gasket Material
Description of Part(s)
Description of Part
a steel transmission valve-body plate
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 100% by volume solution of ArmaKleen™ Paint and Ink Remover at 160°F in an Ultrasonic Washer for a minimum of 4+ hours.