Skip to main content
Before
After

Cleaning Trial Summary

Segment
:: TSR #13-A-003

 

Customer Objective

The customer was looking to improve their cleaning performance, automate their cleaning process, reduce rework and reject rate and reduce their cleaning costs.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160⁰F
Industry
Time Required
Industry
Diesel remanufacturing
Time Required
45 minutes
Segment
Substrate
Dealership
Steel
Soil
, Rust/Oxides
Description of Part(s)
Description of Part
Assorted steel engine injector parts
Cleaner Used

10% by volume ARMAKLEEN™ M-301

Machine Used
Machine Used

Ultrasonic Washer (SK 6315 Blackstone model 3523)

Post Cleaning
Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommended using 10% by volume ArmaKleen™ M-301 at 160⁰F in an Ultrasonic Washer for a minimum of 45 minutes.