Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #17-A-089

 

Customer Objective

The customer was looking to improve their cleaning performance, automate their cleaning process and reduce their cleaning costs.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Aerospace Manufacturing
Time Required
30 minutes to 1 hour
Segment
Substrate
Fabricated Metal Product
Aluminum
Soil
Baked on Carbon Grime Oil, Shop Dirt
Description of Part(s)
Description of Part
an assortment of aluminum plates and connectors
Cleaner Used
Machine Used
Machine Used

Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000

Post Cleaning
Post Cleaning

Fresh rinse followed by air pressure drying.  Several areas of the aluminum plate w/

connectors had the rim edges lightly brushed with a nylon bristle brush during the fresh water rinse.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-100 BCR at 160°F in a Spray Washer for a minimum of 30 minutes to 1 hour.